import esphome.codegen as cg import esphome.config_validation as cv from esphome.components import sensor, uart from esphome.const import (CONF_ID, CONF_PM_10_0, CONF_PM_2_5, CONF_RX_ONLY, CONF_UPDATE_INTERVAL, UNIT_MICROGRAMS_PER_CUBIC_METER, ICON_CHEMICAL_WEAPON) DEPENDENCIES = ['uart'] sds011_ns = cg.esphome_ns.namespace('sds011') SDS011Component = sds011_ns.class_('SDS011Component', uart.UARTDevice, cg.Component) def validate_sds011_rx_mode(value): if CONF_UPDATE_INTERVAL in value and not value.get(CONF_RX_ONLY): update_interval = value[CONF_UPDATE_INTERVAL] if update_interval.total_minutes > 30: raise cv.Invalid("Maximum update interval is 30min") elif value.get(CONF_RX_ONLY) and CONF_UPDATE_INTERVAL in value: # update_interval does not affect anything in rx-only mode, let's warn user about # that raise cv.Invalid("update_interval has no effect in rx_only mode. Please remove it.", path=['update_interval']) return value CONFIG_SCHEMA = cv.All(cv.Schema({ cv.GenerateID(): cv.declare_id(SDS011Component), cv.Optional(CONF_PM_2_5): sensor.sensor_schema(UNIT_MICROGRAMS_PER_CUBIC_METER, ICON_CHEMICAL_WEAPON, 1), cv.Optional(CONF_PM_10_0): sensor.sensor_schema(UNIT_MICROGRAMS_PER_CUBIC_METER, ICON_CHEMICAL_WEAPON, 1), cv.Optional(CONF_RX_ONLY, default=False): cv.boolean, cv.Optional(CONF_UPDATE_INTERVAL): cv.positive_time_period_minutes, }).extend(cv.COMPONENT_SCHEMA).extend(uart.UART_DEVICE_SCHEMA), validate_sds011_rx_mode) def to_code(config): var = cg.new_Pvariable(config[CONF_ID]) yield cg.register_component(var, config) yield uart.register_uart_device(var, config) if CONF_UPDATE_INTERVAL in config: cg.add(var.set_update_interval_min(config[CONF_UPDATE_INTERVAL])) cg.add(var.set_rx_mode_only(config[CONF_RX_ONLY])) if CONF_PM_2_5 in config: sens = yield sensor.new_sensor(config[CONF_PM_2_5]) cg.add(var.set_pm_2_5_sensor(sens)) if CONF_PM_10_0 in config: sens = yield sensor.new_sensor(config[CONF_PM_10_0]) cg.add(var.set_pm_10_0_sensor(sens))