import esphome.codegen as cg import esphome.config_validation as cv from esphome.components import sensor, voltage_sampler from esphome.const import CONF_SENSOR, CONF_ID, ICON_FLASH, UNIT_AMPERE AUTO_LOAD = ['voltage_sampler'] CONF_SAMPLE_DURATION = 'sample_duration' ct_clamp_ns = cg.esphome_ns.namespace('ct_clamp') CTClampSensor = ct_clamp_ns.class_('CTClampSensor', sensor.Sensor, cg.PollingComponent) CONFIG_SCHEMA = sensor.sensor_schema(UNIT_AMPERE, ICON_FLASH, 2).extend({ cv.GenerateID(): cv.declare_id(CTClampSensor), cv.Required(CONF_SENSOR): cv.use_id(voltage_sampler.VoltageSampler), cv.Optional(CONF_SAMPLE_DURATION, default='200ms'): cv.positive_time_period_milliseconds, }).extend(cv.polling_component_schema('60s')) def to_code(config): var = cg.new_Pvariable(config[CONF_ID]) yield cg.register_component(var, config) yield sensor.register_sensor(var, config) sens = yield cg.get_variable(config[CONF_SENSOR]) cg.add(var.set_source(sens)) cg.add(var.set_sample_duration(config[CONF_SAMPLE_DURATION]))