Add support for BMP388 / BMP 390 pressure and temperature sensor (#2716)
This commit is contained in:
@@ -0,0 +1,100 @@
|
||||
import esphome.codegen as cg
|
||||
import esphome.config_validation as cv
|
||||
from esphome.components import i2c, sensor
|
||||
from esphome.const import (
|
||||
CONF_ID,
|
||||
CONF_IIR_FILTER,
|
||||
CONF_OVERSAMPLING,
|
||||
CONF_PRESSURE,
|
||||
CONF_TEMPERATURE,
|
||||
DEVICE_CLASS_PRESSURE,
|
||||
DEVICE_CLASS_TEMPERATURE,
|
||||
STATE_CLASS_MEASUREMENT,
|
||||
UNIT_CELSIUS,
|
||||
UNIT_HECTOPASCAL,
|
||||
)
|
||||
|
||||
CODEOWNERS = ["@martgras"]
|
||||
DEPENDENCIES = ["i2c"]
|
||||
|
||||
bmp3xx_ns = cg.esphome_ns.namespace("bmp3xx")
|
||||
Oversampling = bmp3xx_ns.enum("Oversampling")
|
||||
OVERSAMPLING_OPTIONS = {
|
||||
"NONE": Oversampling.OVERSAMPLING_NONE,
|
||||
"2X": Oversampling.OVERSAMPLING_X2,
|
||||
"4X": Oversampling.OVERSAMPLING_X4,
|
||||
"8X": Oversampling.OVERSAMPLING_X8,
|
||||
"16X": Oversampling.OVERSAMPLING_X16,
|
||||
"32x": Oversampling.OVERSAMPLING_X32,
|
||||
}
|
||||
|
||||
IIRFilter = bmp3xx_ns.enum("IIRFilter")
|
||||
IIR_FILTER_OPTIONS = {
|
||||
"OFF": IIRFilter.IIR_FILTER_OFF,
|
||||
"2X": IIRFilter.IIR_FILTER_2,
|
||||
"4X": IIRFilter.IIR_FILTER_4,
|
||||
"8X": IIRFilter.IIR_FILTER_8,
|
||||
"16X": IIRFilter.IIR_FILTER_16,
|
||||
"32X": IIRFilter.IIR_FILTER_32,
|
||||
"64X": IIRFilter.IIR_FILTER_64,
|
||||
"128X": IIRFilter.IIR_FILTER_128,
|
||||
}
|
||||
|
||||
BMP3XXComponent = bmp3xx_ns.class_(
|
||||
"BMP3XXComponent", cg.PollingComponent, i2c.I2CDevice
|
||||
)
|
||||
|
||||
CONFIG_SCHEMA = (
|
||||
cv.Schema(
|
||||
{
|
||||
cv.GenerateID(): cv.declare_id(BMP3XXComponent),
|
||||
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_CELSIUS,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_TEMPERATURE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
).extend(
|
||||
{
|
||||
cv.Optional(CONF_OVERSAMPLING, default="2X"): cv.enum(
|
||||
OVERSAMPLING_OPTIONS, upper=True
|
||||
),
|
||||
}
|
||||
),
|
||||
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_HECTOPASCAL,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_PRESSURE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
).extend(
|
||||
{
|
||||
cv.Optional(CONF_OVERSAMPLING, default="16X"): cv.enum(
|
||||
OVERSAMPLING_OPTIONS, upper=True
|
||||
),
|
||||
}
|
||||
),
|
||||
cv.Optional(CONF_IIR_FILTER, default="OFF"): cv.enum(
|
||||
IIR_FILTER_OPTIONS, upper=True
|
||||
),
|
||||
}
|
||||
)
|
||||
.extend(cv.polling_component_schema("60s"))
|
||||
.extend(i2c.i2c_device_schema(0x77))
|
||||
)
|
||||
|
||||
|
||||
async def to_code(config):
|
||||
var = cg.new_Pvariable(config[CONF_ID])
|
||||
await cg.register_component(var, config)
|
||||
await i2c.register_i2c_device(var, config)
|
||||
cg.add(var.set_iir_filter_config(config[CONF_IIR_FILTER]))
|
||||
if CONF_TEMPERATURE in config:
|
||||
conf = config[CONF_TEMPERATURE]
|
||||
sens = await sensor.new_sensor(conf)
|
||||
cg.add(var.set_temperature_sensor(sens))
|
||||
cg.add(var.set_temperature_oversampling_config(conf[CONF_OVERSAMPLING]))
|
||||
|
||||
if CONF_PRESSURE in config:
|
||||
conf = config[CONF_PRESSURE]
|
||||
sens = await sensor.new_sensor(conf)
|
||||
cg.add(var.set_pressure_sensor(sens))
|
||||
cg.add(var.set_pressure_oversampling_config(conf[CONF_OVERSAMPLING]))
|
||||