Convert sensor_schema to use kwargs (#2094)

Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
Otto Winter
2021-08-01 12:21:32 +02:00
committed by GitHub
parent 81ae6709e4
commit 5c65f9f9ad
115 changed files with 1337 additions and 1371 deletions
@@ -12,7 +12,6 @@ from esphome.const import (
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_VOLTAGE,
ICON_EMPTY,
UNIT_CELSIUS,
UNIT_PERCENT,
UNIT_VOLT,
@@ -33,16 +32,24 @@ CONFIG_SCHEMA = (
cv.GenerateID(): cv.declare_id(PVVXMiThermometer),
cv.Required(CONF_MAC_ADDRESS): cv.mac_address,
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
UNIT_CELSIUS, ICON_EMPTY, 2, DEVICE_CLASS_TEMPERATURE
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
),
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
UNIT_PERCENT, ICON_EMPTY, 2, DEVICE_CLASS_HUMIDITY
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=2,
device_class=DEVICE_CLASS_HUMIDITY,
),
cv.Optional(CONF_BATTERY_LEVEL): sensor.sensor_schema(
UNIT_PERCENT, ICON_EMPTY, 0, DEVICE_CLASS_BATTERY
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=0,
device_class=DEVICE_CLASS_BATTERY,
),
cv.Optional(CONF_BATTERY_VOLTAGE): sensor.sensor_schema(
UNIT_VOLT, ICON_EMPTY, 3, DEVICE_CLASS_VOLTAGE
unit_of_measurement=UNIT_VOLT,
accuracy_decimals=3,
device_class=DEVICE_CLASS_VOLTAGE,
),
}
)