BH1750 dynamically calculate options (#3214)
* BH1750 dynamically calculate options * Fix tests * Fix NAN * Convert setup to new-style * Add myself as codeowner
This commit is contained in:
@@ -2,28 +2,20 @@ import esphome.codegen as cg
|
||||
import esphome.config_validation as cv
|
||||
from esphome.components import i2c, sensor
|
||||
from esphome.const import (
|
||||
CONF_RESOLUTION,
|
||||
DEVICE_CLASS_ILLUMINANCE,
|
||||
STATE_CLASS_MEASUREMENT,
|
||||
UNIT_LUX,
|
||||
CONF_MEASUREMENT_DURATION,
|
||||
)
|
||||
|
||||
DEPENDENCIES = ["i2c"]
|
||||
CODEOWNERS = ["@OttoWinter"]
|
||||
|
||||
bh1750_ns = cg.esphome_ns.namespace("bh1750")
|
||||
BH1750Resolution = bh1750_ns.enum("BH1750Resolution")
|
||||
BH1750_RESOLUTIONS = {
|
||||
4.0: BH1750Resolution.BH1750_RESOLUTION_4P0_LX,
|
||||
1.0: BH1750Resolution.BH1750_RESOLUTION_1P0_LX,
|
||||
0.5: BH1750Resolution.BH1750_RESOLUTION_0P5_LX,
|
||||
}
|
||||
|
||||
BH1750Sensor = bh1750_ns.class_(
|
||||
"BH1750Sensor", sensor.Sensor, cg.PollingComponent, i2c.I2CDevice
|
||||
)
|
||||
|
||||
CONF_MEASUREMENT_TIME = "measurement_time"
|
||||
CONFIG_SCHEMA = (
|
||||
sensor.sensor_schema(
|
||||
BH1750Sensor,
|
||||
@@ -34,14 +26,11 @@ CONFIG_SCHEMA = (
|
||||
)
|
||||
.extend(
|
||||
{
|
||||
cv.Optional(CONF_RESOLUTION, default=0.5): cv.enum(
|
||||
BH1750_RESOLUTIONS, float=True
|
||||
cv.Optional("resolution"): cv.invalid(
|
||||
"The 'resolution' option has been removed. The optimal value is now dynamically calculated."
|
||||
),
|
||||
cv.Optional(CONF_MEASUREMENT_DURATION, default=69): cv.int_range(
|
||||
min=31, max=254
|
||||
),
|
||||
cv.Optional(CONF_MEASUREMENT_TIME): cv.invalid(
|
||||
"The 'measurement_time' option has been replaced with 'measurement_duration' in 1.18.0"
|
||||
cv.Optional("measurement_duration"): cv.invalid(
|
||||
"The 'measurement_duration' option has been removed. The optimal value is now dynamically calculated."
|
||||
),
|
||||
}
|
||||
)
|
||||
@@ -54,6 +43,3 @@ async def to_code(config):
|
||||
var = await sensor.new_sensor(config)
|
||||
await cg.register_component(var, config)
|
||||
await i2c.register_i2c_device(var, config)
|
||||
|
||||
cg.add(var.set_resolution(config[CONF_RESOLUTION]))
|
||||
cg.add(var.set_measurement_duration(config[CONF_MEASUREMENT_DURATION]))
|
||||
|
||||
Reference in New Issue
Block a user