Add support for SMT100 Soil Moisture Sensor (#3654)
Co-authored-by: Dennis Piecha <d.piecha@ymail.com>
This commit is contained in:
@@ -0,0 +1,94 @@
|
||||
import esphome.codegen as cg
|
||||
import esphome.config_validation as cv
|
||||
from esphome.components import sensor, uart
|
||||
|
||||
from esphome.const import (
|
||||
CONF_ID,
|
||||
CONF_COUNTS,
|
||||
CONF_DIELECTRIC_CONSTANT,
|
||||
CONF_TEMPERATURE,
|
||||
CONF_MOISTURE,
|
||||
CONF_VOLTAGE,
|
||||
ICON_WATER_PERCENT,
|
||||
DEVICE_CLASS_TEMPERATURE,
|
||||
DEVICE_CLASS_VOLTAGE,
|
||||
STATE_CLASS_MEASUREMENT,
|
||||
UNIT_EMPTY,
|
||||
UNIT_CELSIUS,
|
||||
UNIT_PERCENT,
|
||||
UNIT_VOLT,
|
||||
)
|
||||
|
||||
DEPENDENCIES = ["uart"]
|
||||
|
||||
smt100_ns = cg.esphome_ns.namespace("smt100")
|
||||
SMT100 = smt100_ns.class_("SMT100Component", cg.PollingComponent, uart.UARTDevice)
|
||||
|
||||
|
||||
CONFIG_SCHEMA = (
|
||||
cv.Schema(
|
||||
{
|
||||
cv.GenerateID(): cv.declare_id(SMT100),
|
||||
cv.Optional(CONF_COUNTS): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_EMPTY,
|
||||
accuracy_decimals=0,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
cv.Optional(CONF_DIELECTRIC_CONSTANT): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_EMPTY,
|
||||
accuracy_decimals=2,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_CELSIUS,
|
||||
accuracy_decimals=2,
|
||||
device_class=DEVICE_CLASS_TEMPERATURE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
cv.Optional(CONF_MOISTURE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_PERCENT,
|
||||
icon=ICON_WATER_PERCENT,
|
||||
accuracy_decimals=2,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
cv.Optional(CONF_VOLTAGE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_VOLT,
|
||||
accuracy_decimals=2,
|
||||
device_class=DEVICE_CLASS_VOLTAGE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
}
|
||||
)
|
||||
.extend(cv.polling_component_schema("60s"))
|
||||
.extend(uart.UART_DEVICE_SCHEMA)
|
||||
)
|
||||
|
||||
FINAL_VALIDATE_SCHEMA = uart.final_validate_device_schema(
|
||||
"smt100", baud_rate=9600, require_rx=True, require_tx=True
|
||||
)
|
||||
|
||||
|
||||
async def to_code(config):
|
||||
var = cg.new_Pvariable(config[CONF_ID])
|
||||
await cg.register_component(var, config)
|
||||
await uart.register_uart_device(var, config)
|
||||
|
||||
if CONF_COUNTS in config:
|
||||
sens = await sensor.new_sensor(config[CONF_COUNTS])
|
||||
cg.add(var.set_counts_sensor(sens))
|
||||
|
||||
if CONF_DIELECTRIC_CONSTANT in config:
|
||||
sens = await sensor.new_sensor(config[CONF_DIELECTRIC_CONSTANT])
|
||||
cg.add(var.set_dielectric_constant_sensor(sens))
|
||||
|
||||
if CONF_TEMPERATURE in config:
|
||||
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
|
||||
cg.add(var.set_temperature_sensor(sens))
|
||||
|
||||
if CONF_MOISTURE in config:
|
||||
sens = await sensor.new_sensor(config[CONF_MOISTURE])
|
||||
cg.add(var.set_moisture_sensor(sens))
|
||||
|
||||
if CONF_VOLTAGE in config:
|
||||
sens = await sensor.new_sensor(config[CONF_VOLTAGE])
|
||||
cg.add(var.set_voltage_sensor(sens))
|
||||
Reference in New Issue